| FULLY AUTOMATIC SWITCHOVER FUNCTION BETWEEN A PAIR OF TIME & FREQUENCY SOURCES IN THE EVENT OF SIGNAL LOSS. | |
| BUILT IN HIGH-QUALITY SIGNAL DISTRIBUTION FUNCTION, PROVIDING UP TO 10 FREQUENCY (RF), AND 10 TIMING (1HZ) OR 14 RF OUTPUTS IN 1U OF RACK SPACE. | |
| EACH OUTPUT IS DRIVEN BY AN INDEPENDENT BUFFER, AND INDIVIDUALLY MONITORED FOR SIGNAL FAILURE. | |
| MANUAL SWITCHOVER OVERRIDE. | |
| AC AND/OR DC POWERED FROM TIME SOURCES FOR RELIABILITY AND BATTERY BACKUP POSSIBILITY. |
Auto-changeover / Distribution Units allow duplex operation of two 1804s,
and in
addition provide up to 10 pairs of Timing and Frequency outputs.
Companion Unit To 1804 / 1814 / 2804 GPS Time & Frequency Sources
19" Rack-Mount x 1U Height
Provides
full-duplex Master/Standby operation with two sources.
Auto-changeover and Distribution with
10 Frequency and 10 Timing Outputs
Fault alarm output -- All inputs and
outputs monitored
![]()
1876 / 1896 Series -- Signal Distribution units
| DC AND AC POWERED VARIANTS. | |
| VARIANTS FOR FREQUENCY AND TIMECODE DISTRIBUTION. | |
| UP TO 14 OUTPUTS IN A 1U MODULE. | |
| MAY BE POWERED FROM 1804 DC OUTPUT. |
Provide cost effective signal distribution for Timing and Frequency
signals with up
to 10 outputs.
Companion Unit To 1804 / 1814 / 2804 GPS Time & Frequency Sources
19" Rack-Mount x 1U Height
Distribution
-- 10 Frequency and 10 Timing outputs
Fault alarm output -- Input and all
outputs monitored
![]()
900 Series
Click here for
datasheet of 900 Series
![]()
Distribution amplifiers for cost effective local distribution of sinewave reference frequency to multiple outputs.
The 900 series line distribution amplifiers have been designed primarily for the
cost effective local distribution of a 10MHz sinewave reference frequency to multiple outputs.
They can also be configured for 5MHz or 1MHz reference frequency.
The 3U high 19" rack mount or free standing case can accommodate up to 30 outputs.
The input amplifier Type 910 conditions the line input reference signal and distributes it to the five distribution amplifiers Type 909, each having six outputs. The 910 has an additional output which can be utilised to drive a second 30-way assembly. All outputs are monitored and an output amplitude fault is indicated by a LED for each output. A composite alarm is provided on the rear panel of the 911 power supply unit.
|
Rapco's policy is one of continual improvement. We therefore reserve the right to make changes to specifications without notice.
For further information please contact: |
||||||||||||||||||||||||
|
||||||||||||||||||||||||
| |||||||||